Electrical Specifications
Bilge Switch Plug and Play Tank Calibration Customer Feedback
Electrical Specifications
Home Heritage Products What's New Distributors Warranty Downloads Contact

Electrical Specifications

SPT-001 Programmable Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 12 mA @ 12 Volts

  • Output Load = 40 amps @ 12 Volts

  • Input Trigger = 5 ~ 37 Volts DC

  • Input = Voltage & EMI Protected

  • Reverse Polarity Protected

  • Data Retention = 40 years (without power)

SDP-003 Dual Programmable Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 12 mA @ 12 Volts

  • Output Load = 40 amps @ 12 Volts

  • Input Trigger = 5 ~ 37 Volts DC

  • Input = Voltage & EMI Protected

  • Reverse Polarity Protected

  • Data Retention = 40 years (without power)

STS-220 Two-Stage Programmable Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 12 mA @ 12 Volts

  • Output Load = 40 amps @ 12 Volts

  • Input Trigger = 5 ~ 37 Volts DC

  • Input = Voltage & EMI Protected

  • Reverse Polarity Protected

  • Data Retention = 40 years (without power)

SMF-001 Toilet Controller Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = Zero Amps

  • Output Load = 40 amps @ 12 Volts

  • Voltage & EMI Protected

  • Reverse Polarity Protected

  • Data Retention = 40 years (without power)

ST-220 Deluxe Toilet Controller Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 12 mA @ 12 Volts

  • Motor Output Load = 120 Amps Continuous 240 Amps Peak

  • Valve Output Load = 60 Amps Continuous 120 Amps Peak

  • Voltage & EMI Protected

  • Data Retention = 40 years (without power)

ST-660 Holding Tank Controller Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 12 mA @ 12 Volts

  • Discharge Pump Output Load = 80 Amps

  • Aux Output Load = 20 Amps

  • Voltage & EMI Protected

  • Data Retention = 40 years (without power)

HT-100 & HT-100/P Tank Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 10 milliamps (stand-by)

  • Pump Output = 88 amps

  • High relay rated at 3 amps inductive load

  • Reverse Polarity Protected

  • EMI Protected

TM-4000 Four Channel Tank Monitor/Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 12 milliamps (without backlight)

  • Backlight

  • Max network cable length = 1000m

  • Reverse Polarity Protected

  • Input = Voltage & EMI Protected

  • Data Retention = 40 years (without power)

TD-4000 Four Channel Tank and Battery Monitor


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 12 milliamps (without backlight)

  • Backlight

  • Max network cable length = 1000m

  • Reverse Polarity Protected

  • Input = Voltage & EMI Protected

  • Data Retention = 40 years (without power)

TC-8000 Eight Channel Tank Monitor/Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 35 mAmps (Backlight = Off)

  • Max network cable length = 1000m

  • Reverse Polarity Protected

  • Input = Voltage & EMI Protected

  • Data Retention = 50 years (without power)

BC-8000 Eight Channel Bilge Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 35 mAmps (Backlight = Off)

  • Max network cable length = 1000m

  • Output Load per Channel = 60 amps @ 12 Volts DC

  • Input Trigger = 5 ~ 37 Volts DC

  • Reverse Polarity Protected

  • Input = Voltage & EMI Protected

AL-8000 Alarm Monitor Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 35 mAmps (Backlight = Off)

  • Max network cable length = 1000m

  • Reverse Polarity Protected

  • Input = Voltage & EMI Protected

NV-8000 Navigational Alarm Monitor/Controller Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 35 mAmps (Backlight = Off)

  • Max network cable length = 1000m

  • Reverse Polarity Protected

  • Input = Voltage & EMI Protected

NV-2000 Navigational Alarm Monitor Specifications


  • Supply Voltage = 12 to 32 Volts DC (Auto sensing)

  • Quiescent Current = 12 milliamps (without backlight)

  • Backlight

  • Max network cable length = 1000m

  • Reverse Polarity Protected

  • Input = Voltage & EMI Protected

  • Data Retention = 40 years (without power)

FS2A Water Sensor Specifications


  • Switching Capacity, Max Watts 50
  • Switching Capacity, Max Volts dc 200
  • Switching Capacity, Max Volts ac 200
  • Switching Capacity, Max Amps 0.5
  • Contact Form Normally Open
  • Max. Operating Temp. Degrees C 80
  • Material PP
  • Useful Specific Gravity 0.7
  • Trigger Depth: Approx 10mm

Back to top | Electrical Specifications | Boat & Marine Gauges Home