SPT-001 Programmable Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 12 mA @ 12 Volts
-
Output Load = 40 amps @ 12 Volts
-
Input Trigger = 5 ~ 37 Volts DC
-
Input = Voltage & EMI Protected
-
Reverse Polarity Protected
-
Data Retention = 40 years (without power)
|
SDP-003 Dual Programmable Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 12 mA @ 12 Volts
-
Output Load = 40 amps @ 12 Volts
-
Input Trigger = 5 ~ 37 Volts DC
-
Input = Voltage & EMI Protected
-
Reverse Polarity Protected
-
Data Retention = 40 years (without power)
|
STS-220 Two-Stage Programmable Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 12 mA @ 12 Volts
-
Output Load = 40 amps @ 12 Volts
-
Input Trigger = 5 ~ 37 Volts DC
-
Input = Voltage & EMI Protected
-
Reverse Polarity Protected
-
Data Retention = 40 years (without power)
|
SMF-001 Toilet Controller Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = Zero Amps
-
Output Load = 40 amps @ 12 Volts
-
Voltage & EMI Protected
-
Reverse Polarity Protected
-
Data Retention = 40 years (without power)
|
ST-220 Deluxe Toilet Controller Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 12 mA @ 12 Volts
-
Motor Output Load = 120 Amps Continuous 240 Amps Peak
-
Valve Output Load = 60 Amps Continuous 120 Amps Peak
-
Voltage & EMI Protected
-
Data Retention = 40 years (without power)
|
ST-660 Holding Tank Controller Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 12 mA @ 12 Volts
-
Discharge Pump Output Load = 80 Amps
-
Aux Output Load = 20 Amps
-
Voltage & EMI Protected
-
Data Retention = 40 years (without power)
|
HT-100 & HT-100/P Tank Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 10 milliamps (stand-by)
-
Pump Output = 88 amps
-
High relay rated at 3 amps inductive load
-
Reverse Polarity Protected
-
EMI Protected
|
TM-4000 Four Channel Tank Monitor/Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 12 milliamps (without backlight)
-
Backlight
-
Max network cable length = 1000m
-
Reverse Polarity Protected
-
Input = Voltage & EMI Protected
-
Data Retention = 40 years (without power)
|
TD-4000 Four Channel Tank and Battery Monitor
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 12 milliamps (without backlight)
-
Backlight
-
Max network cable length = 1000m
-
Reverse Polarity Protected
-
Input = Voltage & EMI Protected
-
Data Retention = 40 years (without power)
|
TC-8000 Eight Channel Tank Monitor/Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 35 mAmps (Backlight = Off)
-
Max network cable length = 1000m
-
Reverse Polarity Protected
-
Input = Voltage & EMI Protected
-
Data Retention = 50 years (without power)
|
BC-8000 Eight Channel Bilge Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 35 mAmps (Backlight = Off)
-
Max network cable length = 1000m
-
Output Load per Channel = 60 amps @ 12 Volts DC
-
Input Trigger = 5 ~ 37 Volts DC
-
Reverse Polarity Protected
-
Input = Voltage & EMI Protected
|
|
AL-8000 Alarm Monitor Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 35 mAmps (Backlight = Off)
-
Max network cable length = 1000m
-
Reverse Polarity Protected
-
Input = Voltage & EMI Protected
|
NV-8000 Navigational Alarm Monitor/Controller Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 35 mAmps (Backlight = Off)
-
Max network cable length = 1000m
-
Reverse Polarity Protected
-
Input = Voltage & EMI Protected
|
NV-2000 Navigational Alarm Monitor Specifications
|
-
Supply Voltage = 12 to 32 Volts DC (Auto sensing)
-
Quiescent Current = 12 milliamps (without backlight)
-
Backlight
-
Max network cable length = 1000m
-
Reverse Polarity Protected
-
Input = Voltage & EMI Protected
-
Data Retention = 40 years (without power)
|
FS2A Water Sensor Specifications
|
- Switching Capacity, Max Watts 50
- Switching Capacity, Max Volts dc 200
- Switching Capacity, Max Volts ac 200
- Switching Capacity, Max Amps 0.5
- Contact Form Normally Open
- Max. Operating Temp. Degrees C 80
- Useful Specific Gravity 0.7
- Trigger Depth: Approx 10mm
Back to top | Electrical Specifications | Boat & Marine Gauges Home
|